10/18/2016

0 Comments

 
PictureFigure 1: Water movement and composition of a peristaltic pump
Collecting water samples is a key component to the HMGA Water Project as it provides data necessary to compare treatment processes. Samples are taken before anything was added as well as after the installation of new treatment technologies.  By comparing the results, the efficiency of the new technology was determined.

Auto-samplers were introduced during the project in order to collect samples throughout a given production day. They are used to collect samples at various times without the user needing to be present.  Grab samples were collected along with composite samples to provide a clear image of a day’s worth of washing.

HMGA Water Project & Auto-Samplers
The project utilized two types of auto-samplers: the Hach Sigma 900 and the MasterFlex E/C Composite Sampler.  These two auto-samplers were utilized due to their ease of use and reliability. Both types of auto-samplers use peristaltic pumps to pull the water from the collection point through the hose to the bottle. All samples collected using the auto-samplers are composite samples; composite samples are a multitude of single samples combined.  The composite samples were compared to results from manual grab samples.

The auto-samplers were set at varying intervals based on requirements of the day.  On regular sampling days, the auto-samplers were set to take samples every half hour for twelve hours. Alternatively, the auto-samplers were set to draw a sample every ten minutes for three hours during the project’s intensive sampling days.

Peristaltic pumps
As discussed previously, the auto-samplers use peristaltic pumps to draw the water up the hose or tube.  The pump works by pinching a flexible tube around rotors which rotate creating a suction on the water.  As shown in Figure 1, the rotors move in a counter-clockwise rotation, creating suction, thus pulling the water up the tube. 
​
Conclusion
The use of auto-samplers was integral to the success of the HMGA Water Project.  They offer a user-friendly method to take samples that can be used in a variety of situations.  

0 Comments



Leave a Reply.

    Project Updates

    Find articles on project-related topics here

    Archives

    December 2016
    October 2016
    September 2016
    July 2016
    June 2016
    May 2016
    April 2016
    March 2016
    February 2016
    January 2016
    December 2015
    November 2015
    October 2015
    September 2015
    August 2015
    July 2015
    June 2015
    May 2015
    April 2015
    March 2015
    February 2015
    January 2015
    December 2014
    November 2014
    October 2014
    September 2014

    Topics

    All
    Aerators
    Coagulation & Flocculation
    Deionization
    Discharge Characterization
    Drum Filter
    Filter Bags
    General Information
    Hydrocyclone
    Lake Simcoe
    Lesson Learned
    Muck
    Nottawasaga Valley
    Pre Treatment
    Pre-Treatment
    Sampling
    Settling Ponds/Tanks
    South-Eastern Georgian Bay
    System Evaluation
    Treatment Technologies
    Ultrafiltration
    Washing Process
    Water Quality Parameters
    Watershed

    RSS Feed

    Article Titles

    Introduction to
      Watersheds

    Lake Simcoe Watershed
    Nottawasaga Valley
      Watershed
    South-Eastern Georgian
      Bay Watershed
    Water, Water,
      Everywhere?
    The Trouble with Muck:
      Size
    Lesson Learned: Bottom-
      up Aerator to Treat
      Washwater in Settling
      Tanks
    Phosphorus, the
      Environment, and
      Farming
    Nitrogen’s Impact on Air,
      Land, and Water
    Water-borne Pathogens
      and Food Safety
    Defining Dissolved
      Oxygen
    Filter Bags
      Demonstration Site
    Organic Matter
      Breakdown &
      Biochemical Oxygen
      Demand
    Dealing with Cloudy
      Water
    Hydrocyclone
      Demonstration Test
    What IS Muck?
    Demystifying Oxidation-
      Reduction Potential
    News Release
      "Technology
      Investigation: Filter
      Bags"
    Drum Filter
      Demonstration Site
    Decomposing With(out)
      Oxygen
    Flow monitoring
    Lesson Learned: Drum
      Filter Optimization
    Polders & the Holland
      Marsh
    Vegetable Washing
      Process
    ​Dry Soil Removal
    Ultrafiltration &
      Deionization
      Demonstration Site
    News Release
      "Technology
      Investigation:
      Ultrafiltration &
      Capacitive Deionization"
    Progressive Passive
      Filtration
    ​Dissolved Air Flotation
    Clarifying the Solid
      Removal Process
    Factsheet Reading Order
    News Release:
      "Technology
      Investigation:
      Coagulation &
      Flocculation"
    Self-Indexing Filter
    Monitoring Discharge
    ​  Flows
    Settling Soil
    Mass Loading
      Calculations
    Lesson Learned:
      Technology Selection
    Electrocoagulation
    Auto-Samplers
Powered by Create your own unique website with customizable templates.